90 Read the precautions on pages 7 to 12 in the introduction before use. GMMD34502 Series Chemical liquid manual valve (manifold/branch valve) Subject to Export Trade Control Ordinances *Target: GMMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Chemical liquids, pure water (Note 1) 5 to 90 (Note 3) 1.2 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60 Free Ø14.7 to Ø16 (Note 2) ODØ10 tube connection (fitting integrated type) ODØ12 tube connection…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors ■ Measuring range 50...2000 °C ■ Analog and switching output ■ Fibre-optic up to 350 °C ■ For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60214 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm,…
File type: application/pdf
Referenced at:
Special-Sensors for Automation ISO 9001 certified Infrared Detect ors Measuring-range 50...2000 °C Analog and switching output Fibre-optic up to 350 °C For heavy industry - IP 68 EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com6.02 EE60410 Function and application Where conventional sensors would fail due to too high temperature, infrared detectors working on a non-contact principle can be used. They respond to the radiated heat of the hot materials. Compact units with optics are used for distances of 2 to 8 m from the object. For distances of only a few cm, heat-resistant…
File type: application/pdf
Referenced at:
Special-Sensors for Automation Level Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com2.02 E20817 We reserve the right to make technical alterations without prior notice. Level Sensors Contents Application notes...................................................................................................... 2.03 - 2.07 Level Sensors Microwave meter Series MFP ............................................................................................. 2.08 - 2.12 Microwave meter Series MFM…
File type: application/pdf
Referenced at:
Special-Sensors for Automation Level Sensors EGE-Elektronik Spezial-Sensoren GmbH • http://www.ege-elektronik.com2.02 E20817 We reserve the right to make technical alterations without prior notice. Level Sensors Contents Application notes...................................................................................................... 2.03 - 2.07 Level Sensors Microwave meter Series MFP ............................................................................................. 2.08 - 2.12 Microwave meter Series MFM…
File type: application/pdf
Referenced at:
Profile Rail Linear Guides 500 Series Ball Profile Rail, 500 Series Roller Profile Rail, 400 Series Profile Rail, AccuMini, MicroGuide, T-Series Profile Rail Linear Guides www.thomsonlinear.com Thomson – the Choice for Optimized Motion Solutions Often the ideal design solution is not about finding the fastest, sturdiest, most accurate or even the least expensive option. Rather, the ideal solution is the optimal balance of performance, life and cost. The Best Positioned Supplier of Mechanical Motion Technology Thomson has several advantages that makes us the supplier of choice for motion…
File type: application/pdf
Referenced at:
Profile Rail Linear Guides 500 Series Ball Profile Rail, 500 Series Roller Profile Rail, 400 Series Profile Rail, AccuMini, MicroGuide, T-Series Profile Rail Linear Guides www.thomsonlinear.com Thomson – the Choice for Optimized Motion Solutions Often the ideal design solution is not about finding the fastest, sturdiest, most accurate or even the least expensive option. Rather, the ideal solution is the optimal balance of performance, life and cost. The Best Positioned Supplier of Mechanical Motion Technology Thomson has several advantages that makes us the supplier of choice for motion…
File type: application/pdf
Referenced at:
VACUUM SOLUTIONS VACUUM SOLUTIONS c a t á l o g o 2 Lo s d ibu jos en 3D es tá n d isp on ibl es en el si tio w eb vu ot ot ec nic a.n et MICROPORTAVENTOSAS PÁG. 2.01 PORTAVENTOSAS MINI PÁG. 2.02 ÷ 2.08 PORTAVENTOSAS MINI PARA VENTOSAS DE FUELLE PÁG. 2.09 ÷ 2.16 PORTAVENTOSAS MINI CON CONEXIONES ROSCADAS MACHO Y HEMBRA PÁG. 2.17 ÷ 2.18 PORTAVENTOSAS MINI CON MUELLE EMPOTRADO PÁG. 2.18 PORTAVENTOSAS MINI CON CARRERA REDUCIDA PÁG. 2.19 ÷ 2.21 PORTAVENTOSAS MINI CON CASQUILLO EMPOTRABLE PÁG. 2.22 ÷ 2.23 PORTAVENTOSAS MINI CON CASQUILLO EMPOTRABLE, CON CONEXIONES ROSCADAS MACHO Y HEMBRA PÁG. 2.24…
File type: application/pdf
Referenced at:
48 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: GAMD3*2 Ø6 to Ø10 GAMD4*2 Ø14.7 to Ø16 GAMD5*2 Ø20 No. of stations: 1 to 5 stations GAMD345*2 Series Air-operated valve for chemical liquids (manifold/branch valve) Subject to Export Trade Control Ordinances *Target: GAMD4*2 and 5*2 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Operation section Operation pressure range…
File type: application/pdf
Referenced at: